Magnetic Flow Meter

Item No.:DG-EFM001

MOQ:1 pc


Overview

The electromagnetic flow meter is suited for flow measurement of all liquids with a minimum conductivity of 5 µS/cm, like chemicals, water with mud, beverages, rough and drink water and others. The flow measurement is independent of density, temperature, pressure and viscosity of the medium.


The operating principle of the electromagnetic flow meter is based on Faraday's law of magnetic induction.


Technical Specifications

Product

DG-EFM001 Series

Size

DN15 – DN800

Medium

Conductive liquid, slurry

Medium Temperature

≤120℃, 180℃

Conductivity

≥5μS/cm

Accuracy

±0.3%, ±0.5%

Repeatability

±0.1%, ±0.2%

Rated Pressure

1.0, 1.6, 2.0MPa ( or specified by customer)

Display

Instantaneous flowrate, total flow, diagnotics

Signal Output

Analog 4 - 20mA, isolated
Totalization pulses, frequency 0 - 5kHz, communication RS485

Power Supply

85-265V AC/DC/3.6V

Converter Type

Compact / Remote

Protection Grade

IP67 /  IP68

Velocity

0.3-10m/s (0.1-12m/s, 0.1 to 0.3 m/s accuracy is ±2.0%)

Liner

Ebonite, Neoprene Gum( DN40-DN1200); Polyurethane( DN25-DN300); F4(DN10-DN1200) ; F46( FEP)(DN15 –DN600); Ceramics(DN15-DN300);

Flowing Direction

Forward, Reverse

Electrode Material

316L, Pt, Ta, Ti, HB, HC

Electrode Type

Standard

Electrode Number

2-4 pcs

Flange Material

SS/ CS

Alarm (N.O.)

Empty, excitation, high/low flowrate limit

Ambient

Temperature: -25~+60℃, Humidity: 5~90%

Communication

RS-485/ModBus, Hart, Profibus-DP, Profibus-PA,GPRS,NB-IoT

 

Ordering Code

DeGao Electromagnetic Flowmeter Ordering Code

 

Model

Ordering Code

Description

DG

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flowmeter Version

I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Integrated

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Remote

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Accuracy class

 

 

0.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.5%

 

 

0.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.3%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Connection Type

 

 

 

DIN

 

 

 

 

 

 

 

 

 

 

 

 

 

DIN

 

 

 

ANSI

 

 

 

 

 

 

 

 

 

 

 

 

 

ANSI

 

 

 

JIN

 

 

 

 

 

 

 

 

 

 

 

 

 

JIN

 

 

 

GB

 

 

 

 

 

 

 

 

 

 

 

 

 

GB

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensor Size

 

 

 

 

DN3

     ......

     800

 

 

 

 

 

 

 

 

 

 

 

 

3mm

     .......

     800mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Liner Material

 

 

 

 

 

HR

 

 

 

 

 

 

 

 

 

 

 

Rubber

 

 

 

 

 

PE

 

 

 

 

 

 

 

 

 

 

 

PTFE

 

 

 

 

 

FE

 

 

 

 

 

 

 

 

 

 

 

FEP

 

 

 

 

 

PO

 

 

 

 

 

 

 

 

 

 

 

Polyurethane

 

 

 

 

 

CE

 

 

 

 

 

 

 

 

 

 

 

Ceramics


 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrode type

 

 

 

 

 

 

http://www.meterschina.com/